Product Liquid Performance
| item | unit | Specification | Test Method |
| Appearance | — | Light yellow transparent liquid | GB/T8237-2005 |
| Acid value | mgKOH/g | 13.0~19.0 | GB/T2895-2008 |
| Viscosity(25℃) | mPa·s | 300~500 | GB/T7193-2008 |
| Solid content | % | 53.0~59.0 | GB/T7193-2008 |
| Gel time* | min | 8.0~14.0 | GB/T7193-2008 |
*Test system: 1.0g COB12 and 2.0g M50 (AKZO-Nobel) were added to 100g resin at 25°C.
Mechanical properties of product casting
| item | unit | Measured value | Test Method |
| Tensile Strength | MPa | 75 | GB/T2567-2008 |
| Tensile Elastic Modulus | MPa | 3200 | GB/T2567-2008 |
| Elongation at Break | % | 3.0 | GB/T2567-2008 |
| Bending Strength | MPa | 125 | GB/T2567-2008 |
| Flexural modulus | MPa | 3300 | GB/T2567-2008 |
| Impact Strength | KJ/㎡ | 14 | GB/T2567-2008 |
| Heat Deformation Temperature | ℃ | 105 | GB/T1634-2004 |
Note:
1) Curing Conditions: Room temperature for 24 hours, post-curing at 40°C, 60°C, and 80°C for 2 hours each, and post-curing at 100°C for 1 hour.
2) Testing Conditions: Temperature 23±2°C, Relative Humidity 50±6%
Usage Precautions
CHEMPOLY® 411 resin does not contain an accelerator. An appropriate amount of accelerator and curing agent must be added based on the operating environment and
requirements. During use, be sure to control the moisture content of materials such as glass fiber, filler, and pigment paste, and pay attention to the compatibility of the
pigment paste with the unsaturated polyester resin.
When using CHEMPOLY® 411 for corrosion-resistant linings, carefully select the appropriate material based on the storage medium and the Kelwell Anticorrosion Manual.
Packaging and Storage
Packaging and Specifications: 200kg/drum; 1000kg/drum.
Shelf Life: 3 months if unopened. Before use, store the resin in its original packaging (to avoid opening or damaging the drum) in a dry room below 25°C.
Temperature fluctuations and exposure to light will significantly reduce the shelf life. Store away from direct sunlight and heat sources. Unsaturated polyester resin
containing styrene is flammable; store away from open flames. Always refer to the safety data sheet.
Product Safety Data Sheet (MSDS) Before using this product, please be sure to read the MSDS carefully.
All data is derived from our in-depth research and extensive practice and is therefore completely reliable. However, due to the multiple factors affecting product production, we assume no responsibility for the actual performance, effects, and impacts of these data, as well as the specific application and processing of these products, or for any direct or indirect losses resulting therefrom. Before purchasing these products, please independently verify the relevant product quality, performance indicators, safety, and other data.